Please use this identifier to cite or link to this item: https://ea.donntu.edu.ua/jspui/handle/123456789/28055
Title: ЭКСПЕРИМЕНТАЛЬНЫЕ ИССЛЕДОВАНИЯ ФАКТОРОВ, ВЛИЯЮЩИХ НА РЕЗУЛЬТАТЫ ИЗМЕРЕНИЙ ПРИ КОНТРОЛЕ ТОЛЩИНЫ МЕТАЛЛОИЗДЕЛИЙ С ТОЛСТЫМИ ДИЭЛЕКТРИЧЕСКИМИ ПОКРЫТИЯМИ ЭМА МЕТОДОМ
Other Titles: Експериментальне дослідження факторів, що впливають на результати вимірювань, при контролі товщини металовиробів з товстими діелектричними покриттями ЕМА методом.
Experimental investigation of influencing factors on results of measurements at metal thickness control with thick dielectric coatings using electromagnetic-acoustic method.
Authors: Г.М. Сучков, G.M. Suchkov
А.В. Десятниченко, O.V. Desyatnichenko
Keywords: ЭМА преобразователь
EMA transducer
металлоизделие
metal product
диэлектрическое покрытие
dielectric coating
генератор
generator
зондирующая последовательность
probe sequence
Issue Date: May-2015
Publisher: Донецький національний технічний університет
Citation: Наукові праці Донецького національного технічного університету. Серія: Обчислювальна техніка та автоматизація. Випуск 1 (28). - Красноармійськ, ДонНТУ, 2015.
Series/Report no.: Наукові праці Донецького національного технічного університету. Серія: Обчислювальна техніка та автоматизація. Випуск 1 (28). - Красноармійськ, ДонНТУ, 2015. - C. 156-164.;
Abstract: Приведены результаты исследований зависимости уровня полезного сигнала от напряжения питания передающей обмотки электромагнитно-акустического преобразователя. Показано, что уровень соотношения сигнал/шум на выходе приемного усилителя пропорционален амплитуде питающего напряжения датчика. Исследована зависимость уровня полезного сигнала, от количества импульсов, при пакетном возбуждении. Показано, что ввиду резонансных свойств датчика имеет место плавное нарастание импульсов при генерации и при приеме. Причем скорость нарастания для принятой последовательности гораздо ниже, чем для генерируемой. Проведено экспериментальное исследование зависимости амплитуды принимаемого сигнала от зазора. Показано, что при увеличении зазора, с 0 до 2 мм наблюдается рост соотношения сигнал/шум для принятых донных импульсов. При дальнейшем увеличении зазора наблюдается значительное падение этой величины.
Description: The experimental investigation of the received signal amplitude relation to the electromagnetic acoustic transducer supply voltage is given. The article shows, that the signal/noise ratio of the received signal is proportional to the signal amplitude on the sensor transmitting coil. Therefore, to achieve high sensitivity control, it is necessary to increase the level of sensor generating coil supply voltage. The dependence of the received signal level from the number of pulses in packetizing mode is given. In the article it is shown, that there is low amplitude increasing speed during generation according to the electromagnetic-acoustic transducer resonance characteristics. Moreover, the rate of increase for the received sequence is much lower than for generated one. Based on the measured data, the number of pulses required in a large gap must be more than or equal to 5-6 impulses. An experimental dependence investigation of the received signal amplitude from the gap ratio is shown. It is shown that during increasing of the gap from 0 to 2 mm, the signal/noise ratio rises. However, during further gap increasing there is a significant drop in the signal/noise ratio value. This occurs because the increasing of the transmission loss of energy is much higher, than increasing of the amplitude at generating coil. This reduces the received signal amplitude. The results of the experiments showed that the minimum number of pulses required for satisfactory registration of the received data is three. Using smaller number is not rational, because the signal amplitude does not reach high values on gaps that more than 2 mm. The optimal number of pulses is 5-7. This value allows making measurements on a wide range of thicknesses. Using the number of pulses over seven does not significantly increase the amplitude of the received signal, but otherwise, it increases the length of the probe sequence, which can lead to an increase in the dead zone. Therefore, an amount value can be used for products with large thickness, in the case when it is impossible to obtain a sufficient signal/ noise ratio with a lower number of pulses.
URI: http://ea.donntu.edu.ua/handle/123456789/28055
ISSN: 2075-4272
Appears in Collections:Випуск 1(28)

Files in This Item:
File Description SizeFormat 
Npdntu_ota_2015_1_21.pdf313,9 kBAdobe PDFView/Open