Title: | Потужність, розсіювана трансформатором напруги за однофазного замикання на землю |
Other Titles: | Мощность, рассеиваемая трансформатором напряжения во время однофазного замыкания на землю Power Dissipation by Voltage Transformer During Single-Phase Ground Fault |
Authors: | Амброз, В.М. Ambroz, V. Базилевич, М.В. Bazylevych, M. Магурчак, Н.І. Магурчак, Н.И. Magurchak, N. Сабадаш, І.О. Сабадаш, И.О Sabadash, I. |
Keywords: | однофазне замикання на землю однофазное замыкание на землю single-phase ground fault мережі з ізольованою нейтраллю сети с изолированной нейтралью sapply with non-grounded neutral трансформатор напруги трансформатор напряжения voltage transformer ферорезонансні процеси феррорезонансные процессы ferorezonansni processes |
Issue Date: | 2013 |
Publisher: | ДонНТУ |
Citation: | Наукові праці Донецького національного технічного університету. Серія "Електротехніка і енергетика". № 2 (15), 2013 р., 338 с. |
Series/Report no.: | Электротехника и энергетика; |
Abstract: | Досліджено процеси пов'язані з розсіянням активної потужності трансформаторами напруги за однофазних замикань на землю. Встановлено розподіл її по обмотках, вплив різниx факторів тa видів замикань на характеристики потужності розсіювання. |
Description: | The processes associated with scattering active power Voltage transformer for single phase earth fault. Established its distribution in the windings, the influence of different factors and types of faults on the characteristics of power dissipation. In normal operational mode scattering power winding higher and lower Voltage is low and depends on the load.. In steady-state mode single phase ground fault power transformer windings scattering depends on the current single phase ground fault, but depends on the load. In steady-state mode single phase ground fault power, which scatter winding side higher voltage is much larger than that dissipate low Voltage winding and "unlock triangle." For single arc fault to earth scattered power is ten times higher than normal. For all this power transformer has the form of wave packets, the intensity of which quickly fades. The biggest impact on the Value of dissipated power parameters have higher Voltage windings and magnetic core magnetization curve. It is anticipated that the regime arc fault the ground is particularly dangerous for TN because there is a large selection of energy in the windings for each penetration and subsequent recovery isolation. To safeguard damaging Voltage transformer for arc fault should be turned off from joining single phase ground fault or Voltage transformer. |