Please use this identifier to cite or link to this item: http://ea.donntu.edu.ua:8080/jspui/handle/123456789/23221
Title: АВТОНОМНЫЙ ИНВЕРТОР ТОКА В КАЧЕСТВЕ ИСТОЧНИКА СИНУСОИДАЛЬНОГО НАПРЯЖЕНИЯ
Other Titles: The Independent Inverter of a Current as a Source of a Sine Wave Voltage
Автономний інвертор струму як джерело синусоїдальної напруги
Authors: ШАВЁЛКИН, А. А.
SHAVELKIN, А.
ШАВЬОЛКІН, О. О.
Keywords: автономний інвертор струму
високовольтний перетворювач частоти
джерело напруги
ключі що замикаються за колом керування
трирівневий релейний регулятор
коефіцієнт гармонік
independent inverter of a current
high-voltage converter of frequency
source of the voltage
gate turnoff switches
three-level relay controller
total harmonic distortion
автономный инвертор тока
высоковольтный преобразователь частоты
источник напряжения
запираемые по цепи управления ключи
трехуровневый релейный регулятор
коэффициент гармоник
Issue Date: 2013
Publisher: ДонНТУ
Citation: Наукові праці Донецького національного технічного університету. Серія "Електротехніка і енергетика". № 1 (14), 2013 р., 358 с.
Abstract: Представлены принципы реализации автономного инвертора тока в режиме источника синусоидального напряжения. Предложено при формировании выходного напряжения инвертора использовать трехуровневые релейные регуляторы, разработан алгоритм управления ключами инвертора. Представлены результаты моделирования инвертора с активным выпрямителем тока на входе при активно-индуктивной нагрузке.
Description: Principles of realization of a mode of a source of a sine wave voltage for the three-phase bridge independent inverter of a current are presented. The scheme of the inverter of a current is executed on gate turn-off switches with unilateral conductivity and output filter on capacitors. The principle of formation of an output voltage of the inverter with use of three-level relay controllers of a voltage is offered. The choice of a working controller is carried out according to the greatest value of a deviation of a voltage of a phase of load from a preset value. It is desirable to use system of control which is astatic for average value of an input current inverter. It is shown, that in view of losses of a voltage in power circuits and a possible voltage reduction of a power link AC the reactive power of the capacitor filter for a nominal mode is no more than 60-65 % from reactive power of the load. The mathematical model of the independent inverter with the active rectifier of a current on the input, which is realizing the offered principles of control, is made. Results of modeling for active-inductive load confirm working capacity of the offered decisions. Value of total harmonic distortion of a voltage is equal (3 - 4) % for frequency of an output voltage of the inverter 50 Hz and for deviation of a voltage from a preset value of 5% is achieve at frequency of switching of switches of the inverter (600 - 1500 Hz). It is shown, that quality of a voltage practically does not depend on value of pulsations of an input current of inverter. It allows reducing inductance of a smoothing reactor in DC link of inverter. Subject of the further researches is development of structure of system of automatic control for the asynchronous electric drive with vector control.
URI: http://ea.donntu.edu.ua/handle/123456789/23221
Appears in Collections:2013_Випуск № 1 (14)
Публікації співробітників кафедри ЕАПУ

Files in This Item:
File Description SizeFormat 
304.pdf332,57 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.