Please use this identifier to cite or link to this item: https://ea.donntu.edu.ua/jspui/handle/123456789/23513
Title: ОЦІНКА ЕФЕКТИВНОСТІ ЗАСТОСУВАННЯ ЛОКАЦІИНОГО МЕТОДУ ДЛЯ ВИЗНАЧЕННЯ МІСЦЯ ПОШКОДЖЕННЯ В МЕРЕЖАХ НАПРУГОЮ 6-35 кВ
Other Titles: Оценка эффективности использования локационного метода для определения места повреждения в сетях напряжением 6-35 кВ
Evaluating the Effectiveness of the Use of Location Method for Determining the Location of the Damage in the Networks of 6-35 kV
Authors: КУТІНА, М.В.
КУТИНА, М. В.
KUTINA, M. V.
Keywords: локаційний метод
складна топологйі
пошук місця пошкодження
автоматизація
ефективність застосування
локационный метод
сложная топология
поиск места повреждения
автоматизация
эффективность применения
location method
complex topology
search the damage
automation
efficiency application
Issue Date: 2013
Publisher: ДонНТУ
Citation: Наукові праці Донецького національного технічного університету. Серія "Електротехніка і енергетика". № 2 (15), 2013 р., 338 с.
Series/Report no.: Электротехника и энергетика;
Abstract: Запропоновано застосування локаціиного методу для визначення місць пошкоджень в мережах напругою 6-35 кВ зі складною топологією. Дано оцінку ефективності застосування локаційного методу при порівнянні його з існуючими методами пошуку місць пошкоджень в мережах напругою 6-35 кВ зі складною топологією.
Description: In this article the evaluation of the effectiveness of location method for fault location in distribution power networks with complex topology voltage 6-35 kV. Evaluation of the effectiveness of location method is carried out by deterrmmng and comparing the reliability of the proposed method for deterrmmng the damage with two basic, which elected based on the need to achieve a certain effect. As a first basic option are used devices Search-l", "wave", "probe", "VPI-l" and others. As a second basic variant of the method proposed successive divide network with optimized algorithm. The calculations for 10 real substations from which retreated 73 lines showed that the application of location method, except social effect to enhance safety operation of distribution networks, allowing comparison with the first base variant, reducing the average search time of the injury site at 2 times the coefficient efficiency is 1.98, increase availability factor by an average of 0.6%, lower coefficient of downtime on average by 40%, increase the ratio of technical applications and operational readiness rate by an average of 0.7%. Compared with the second base variant, using location method reduces loss electricity almost 3 times , coefficients efficiency of decreasing search time location of the damage and loss of electricity are respectively 9.99 and 2.91.
URI: http://ea.donntu.edu.ua/handle/123456789/23513